honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Mainshaft, M/T|Specifications|Page 5466 > < Mainshaft, M/T|Specifications|Page 5464
Page 3
background image

7. Support the 3rd gear on steel blocks, and press the mainshaft out of the 3rd/4th synchro hub as shown.

INSPECT

1. Inspect the gear surface and bearing surface for wear and damage, then measure the mainshaft at points A, B. C, and D.

Standard:

A: 21.987 - 22.000 mm (0.8656 - 0.8661 inch)
B: 26.980 - 26.993 mm (1.0622 - 1.0627 inch)
C: 33.984 - 34.000 mm (1.3380 - 1.3386 inch)
D: 25.977 - 25.990 mm (1.0227 - 1.0232 inch)

Service Limit: 

A: 21.930 mm (0.8634 inch)
B: 26.930 mm (1.0602 inch)
C: 33.930 mm (1.3358 inch)
D: 25.920 mm (1.0205 inch)  

NOTE:  If any part of the mainshaft is less than the service limit, replace it with a new one.

2. Inspect for runout. 

-

Standard (max): 0.02 mm (0.001 inch) 

-

Service Limit: 0.05 mm (0.002 inch)  

NOTE:  Support the mainshaft at both ends as shown. If the runout is more than the service limit, replace the mainshaft with a new one.

ASSEMBLE 

Mainshaft, M/T|Specifications|Page 5466 > < Mainshaft, M/T|Specifications|Page 5464