Crankshaft: Testing and Inspection
End Play Inspection

Connecting Rod and Crankshaft End Play Inspection

1. Remove the oil pump.

2. Measure the connecting rod end play with a feeler gauge between the connecting rod and crankshaft.

Connecting Rod End Play
Standard (New): 0.15 - 0.30 mm (0.006 - 0.012 inch) 
Service Limit: 0.40 mm (0.016 inch)

3. If the connecting rod end play is out-of-tolerance, install a new connecting rod, and recheck. If it is still out-of-tolerance; replace the crankshaft.
4. Mount a dial indicator on the block so that its tip contacts the end of the crankshaft.

5. Push the crankshaft firmly away from the dial indicator, and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back

toward the indicator; the dial reading should not exceed the service limit.
Crankshaft End Play
Standard (New): 0.10 - 0.35 mm (0.004 - 0.014 inch)
Service Limit: 0.45 mm (0.018 inch)

6. If the end play is excessive, replace the thrust washers and recheck. If it is still out-of-tolerance, replace the crankshaft.