Starter Relay: Testing and Inspection

NOTE:  See Turn Signal/Hazard Relay Input Test.

Normally-open type:

Check for continuity between the terminals.

-

There should be continuity between the No.1 and No.3 terminals when power and ground are connected to the No.2 and No.4 terminals.

-

There should be no continuity between the No.1 and No.3 terminals when power is disconnected.