honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Restraint Systems > < Thermal Limiting Fuse|Specifications|Page 7793
Page 1
background image

Thermal Limiting Fuse: Service and Repair

1. Remove the bolt, the ground terminal and the holder. Disconnect the field coil connector, then remove the thermal protector.

2. Replace the thermal protector with a new one, and apply silicone sealant to the bottom of the thermal protector.
3. Install in the reverse order of removal.

Restraint Systems > < Thermal Limiting Fuse|Specifications|Page 7793