CRX DX L4-1493cc 1.5L SOHC (D15B2) TBI (1988)
Air Door Actuator / Motor: Testing and Inspection
Mode Control Motor
Fig. 22 Function control motor.
1.
Connect battery positive to terminal 5 of the control motor connector and negative to terminal 1 Fig. 25 .
2.
Using a jumper wire short terminal 1 and terminals 2, 3, 4, 7 and 8.
4.
The motor Should run each time the short circuit is made.