Thermal Limiting Fuse: Service and Repair

1. Remove the bolt, field coil terminal, and thermal protector retainer.

Thermal Protector Replacement

2. Remove the thermal protector.  Remove the residue of silicone sealant from the top of the thermal protector.

Application Of Silicon Sealant To Thermal Protector

3. Apply silicone sealant to the top of the thermal protector.
4. Install in the reverse order of removal.