6. Connect the SCS service connector (A) to the yellow MES 2P connector (B). Do not use a jumper wire.
7. Turn the ignition switch ON (II).
8. The SRS indicator comes on for about 6 seconds and goes off. Remove the SCS service connector from the MES 2P connector within 4 seconds

after the SRS indicator went off.

9. The SRS indicator comes on again. Reconnect the SCS service connector to the MES 2P connector within 4 seconds after the SRS indicator

comes on.

10. The SRS indicator goes off. Remove the SCS service connector from the MES 2P connector within 4 seconds.
11. Watch the SRS indicator.

-

If the indicator blinks two times and then stays on, the OPDS is initialized, but the DTCs need to be erased. Go to step 12, then erase the
DTCs.

-

If the indicator blinks two times and then goes off, the OPDS unit is initialized. Go to step 12.

-

If the indicator stays on without first blinking, the OPDS is not initialized. Read the DTC. If DTC 15-1 is indicated, repeat the initialization
procedure. If another DTC is indicated, go to the appropriate code in the DTC Troubleshooting. If the OPDS system fails to initialize after
several attempts, replace the OPDS sensor/seat back and retry. If the OPDS system continues to fail to initialize, replace the OPDS unit.

12. Turn the ignition switch off, and disconnect the HDS