Odyssey L4-2.2L SOHC (1995)
Air Door Actuator / Motor: Component Tests and General Diagnostics
Control Motor Test
1. Disconnect the 7P connector from the mode control motor.
2. Connect battery power to the No. 1 terminal, and ground the No. 7 terminal.
CAUTION: Never connect the battery in the opposite direction.
Mode Control Motor Test
3. Using a jumper wire, connect the No. 7 terminal individually to the No. 2, 3, 4, 5 and 6 terminals in that order. Each time the connection is made,
the mode control motor should run smoothly and stop.
NOTE: If the mode control motor does not run when jumping the first terminal, jump that terminal again after jumping the other terminals.
The mode control motor is OK if it runs when jumping the first terminal again.
4. If the mode control motor does not run in step 2, remove it, then check the mode control linkage and doors for smooth movement. If the mode
control linkage and doors move smoothly, replace the mode control motor.
Mode Control Switch
Mode Control Switch Test
Check for continuity between the terminals according to the table.
Control Motor Test
1. Disconnect the 4P connector from the recirculation control motor.