2. Install the ATF guide plate.
3. Install the new bearing into the housing using the special tools as shown.

SECONDARY SHAFT BEARING REPLACEMENT 

1. Remove the secondary shaft bearing by heating the torque converter housing to 212°F (100°C) with a heat gun, then tap the housing until the

bearing falls out.

2. Install the ATF guide plate.