background image

Keyless Entry Module: Testing and Inspection

Power Door Locks/Factory Keyless/Factory Security

Control Unit Input Test

1. Before testing the keyless entry/power door lock control functions, troubleshoot the multiplex control system.

Driver's multiplex Control Unit:

2. Remove the driver's multiplex control unit from the driver's under-dash fuse/relay box.

3. Inspect the connector and socket terminals to be sure they are all making good contact.

-

If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.

-

If the terminals look OK, go to step 4.