ECM Connectors

NOTE:

1.  When a trouble is not found through checks in steps 1 and 2:

^  Clear the memory.
^  Reconnect the circuit properly.
^  Road test the vehicle.
^  Obtain DTC display to see if the trouble has been corrected.
^  If the trouble persists, repeat the OBD System Check.

2.  When making a continuity test or short out test on the circuit, disconnect wiring at the ECM, sensor or the actuator.
3.  When checking ECM harness connector terminals, make connection by inserting the pin at end of the lead. Avoid connecting tester probe directly

to the ECM terminal.

Idle Up Control Valve > < Component Tests and General Diagnostics|Page 1830