Condenser HVAC: Service and Repair

REMOVAL

Preparation:

Battery ground cable
Discharge and recover refrigerant

1. Radiator grille
2. Engine hood front end stay
3. Engine hood lock

-

Apply setting mark to the engine hood lock fixing position before removing it.

4. Pressure switch connector
5. Refrigerant line

-

When removing the line connector, the connecting part should immediately be plugged or capped to prevent foreign matter from being mixed
into the line.

6. Condenser

-

Handle with care to prevent damaging the condenser or radiator fin.

INSTALLATION

6. Condenser

-

If installing a new condenser, be sure to add 30 cc (1.0 fl.oz.) of new compressor oil to a new one.

-

Tighten the condenser fixing bolts to the specified torque.
Torque N.m (lb.in)   6 (52)

5. Refrigerant line

-

Tighten the inlet line to the specified torque.
Torque N.m(lb.ft)   15 (11)

-

Tighten the outlet line to the specified torque.
Torque N.m (lb.ft)   6 (52)

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply new compressor oil to the O-rings when connecting refrigerant line.

4. Pressure switch connector
3. Engine hood lock

-

Install the lock, aligning with the setting marks applied when the lock was removed.

2. Engine hood front end stay
1. Radiator grille