The PCM controls the shift solenoid valves and the A/T clutch pressure control solenoid valves. The conditions of the shift solenoid valves and the
positions of shift valves are as follows:
-

Shift solenoid valve A is turned ON, and shift valve A is in the right side. 

-

Shift solenoid valve B is turned ON, and shift valve B is in the right side. 

-

Shift solenoid valve C is turned OFF, and shift valve C is in the left side. 

The PCM also controls A/T clutch pressure control solenoid valve A to apply LS A pressure (56) to CPC valve A. Line pressure (4) from the manual
valve becomes 2nd clutch pressure (20) at shift valve B. via shift valves C and A. 2nd clutch pressure (20) is applied to the 2nd clutch, and the 2nd
clutch is engaged. The 1st clutch is also engaged. No power is transmitted because of the one-way clutch. 

NOTE:  When used, "left" or "right" indicates direction on the hydraulic circuit. 

[1] Position

ATF Level Check|Page 3488 > < ATF Level Check|Page 3486