14. With a sponge, apply a light coat of glass primer to the edge of the glass (A) and along the rubber darn (B) as shown, then lightly wipe it off with
gauze or cheesecloth
-
Do not apply body primer to the quarter glass, and do not get body and glass primer sponges mixed up.
-
Never touch the primed surfaces with your hands. If you do, the adhesive may not bond to the quarter glass properly, causing a leak after the
quarter glass is installed.
-
Keep water, dust, and abrasive materials away from the primed surfaces.
15. With a sponge, apply a light coat of body primer to the original adhesive remaining around the quarter glass opening flange Let the body primer
dry for at least 10 minutes:
-
Do not apply glass primer to the body, and be careful not to mix Up glass and body printer sponges.
-
Never touch the primed surfaces with your hands.
16. Before filling a cartridge, cut a "V" in the end of the nozzle IA) as shown.