Pilot 4WD V6-3.5L (2008)
Terminal numbers are shown from the wire side of the female terminals. Insert the short canceller(s) into the cavities on the terminal side of the
connector.
Backprobing Spring-loaded Lock Connectors
When checking voltage or resistance on this type of connector the first time, you must remove the retainer to insert the tester probe from the wire side.
NOTE: It is not necessary to reinstall the removed retainer; the terminals will stay locked in the connector housing.
To remove the retainer (A), insert a flat-tip screwdriver (B) between the connector body and the retainer, then carefully pry out the retainer. Take care
not to break the connector.