honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Mode Control Motor|Page 2978 > < Mode Control Motor
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor

Fig. 31 Recirculation control motor.

1.

Connect a jumper wire from the battery positive to terminal 3 of the recirculation control motor and battery negative terminal to terminal 1.

2.

In REC mode, connect a jumper wire from terminal 1 to terminal 4.

3.

In FRESH mode, connect a jumper wire from terminal 1 to terminal 2. If motor fails to run in both modes, motor is defective and must be
replaced.

Mode Control Motor|Page 2978 > < Mode Control Motor