A. Turn the ignition switch ON (II).

B. Check for voltage between communication line and ground:

The voltage should match the table in the image.

^

If the voltage is too high:
A. Check for short to another wire.
B. Check for poor contact at the connector on the receiver side unit.
C. Faulty circuit in the receiver side unit.

^

If the voltage is too low:
A. Check for short to ground or to another wire.
B. Check for poor contact at the connector on the transmit side unit.
C. Faulty circuit in the transmitter side unit.

If any control unit appears to be faulty, select one control unit, substitute a known-good control unit, then recheck. If the system works properly, the
original control unit is faulty; replace it. If there is still a malfunction, substitute a known-good control unit for another control unit, then recheck. If the
system works properly, that control unit is faulty; replace it.

Self-Diagnosis Function (Mode 2)

From mode 1, disconnect the SCS service connector from the multiplex control inspection connector for five to ten seconds, then reconnect the SCS
service connector again, and the function goes from mode 1 to mode 2.
To cancel mode 2, disconnect the SCS service connector from the multiplex control inspection connector for more than 10 seconds or turn the ignition
switch OFF.

1. Operate the switches as shown in mode 2.
2. If the related circuit line of the switch is OK, the function indicates this by the ignition key light and ceiling light blinking once and the beeper

sounding once.

NOTE:  If the line is faulty, there should be no indication. Refer to the tests for each system.

Confirming The Function

1. Shifting to the sleep mode:

1. Turn the ignition switch OFF.
2. Cancel the key-off operation timer in the power window system by opening and closing one of the doors.
3. Make sure that the exterior lights are off.
4. If you do not operate the switches related to the multiplex control units more than one minute after meeting the above conditions, the system

function shifts to the sleep mode.
(All of the switches must be turned OFF except door lock knob switches.)

Initial Inspection and Diagnostic Overview|Page 2566 > < Initial Inspection and Diagnostic Overview|Page 2564