Heated Glass Element Relay: Testing and Inspection

Normally-open type B:

Power Relays-Relay Test

1. Check for continuity between the terminals.

^

There should be continuity between the No.1 and No.3 terminals when power and ground are connected to the No.2 and No.4 terminals.

^

There should be no continuity between the No.1 and No.3 terminals when power is disconnected.

^