Thermal Limiting Fuse: Service and Repair

1. Remove the bolt, the ground terminal and the holder. Disconnect the field coil connector, then remove the thermal protector.

2. Replace the thermal protector with a new one, and apply silicone sealant to the top of the thermal protector.
3. Install in the reverse order of removal.