honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Keyless Entry Module > < Door Lock Relay|Diagrams
Page 1
background image

Door Lock Relay: Testing and Inspection

Five-terminal type A:

1. Check for continuity between the terminals.

^

There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.

^

There should be continuity between the No.1 and No.4 terminals when power is disconnected.

^

Door lock relay