Lifter / Lash Adjuster: Specifications

LEAK DOWN SPECIFICATION

Fall-Down Rate ....................................................................................................................................................................  20 to 50 seconds/2.5 mm

NOTE:
-

Fill and bleed HLA using diesel No.2 oil, or equivalent, with temperature 27°C (81°F).

-

Specification given is for a leak down tester tool No. 09246-32300, or equivalent.