hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Evaporator Case|Removal and Installation|Page 8606 > < Evaporator Case|Locations|Page 8603
Page 1
background image

Evaporator Case: Service and Repair
Removal and Installation

COMPONENTS

REMOVAL

1. Disconnect the battery negative terminal.
2. Discharge the refrigerant.

3. Disconnect the liquid tube "B" and suction hose from the evaporator.

NOTE:  Cap the open fittings immediately to keep moisture and dirt out of the system.

4. Remove the water drain hose from the evaporator.

Evaporator Case|Removal and Installation|Page 8606 > < Evaporator Case|Locations|Page 8603