hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Canister Purge Control Valve|Component Testing|Page 4321 > < Canister Purge Control Valve|Locations|Page 4318
Page 1
background image

Canister Purge Control Valve: Testing and Inspection
Component Testing

EVAP CANISTER PURGE SOLENOID VALVE INSPECTION 

NOTE:  When disconnecting the vacuum hose, make an identification mark on it so that it can be reconnected to its original position.

1. Disconnect the vacuum hose from the solenoid valve.
2. Detach the harness connector.
3. Connect a vacuum pump to the nipple to which the red- striped vacuum hose was connected.

4. Apply vacuum and check when voltage is applied to the evaporative emission canister purge solenoid valve and when the voltage is discontinued.

5. Measure the resistance between the terminals of the solenoid valve.

Coil resistance: 26 ohms @ 20°C (68°F) 

Canister Purge Control Valve|Component Testing|Page 4321 > < Canister Purge Control Valve|Locations|Page 4318