Accent GT Coupe L4-1495cc 1.5L DOHC MFI (1997)
Thermostat: Testing and Inspection
Immerse thermostat in hot coolant to check proper valve opening temperature Replace if necessary.
Valve opening temperature 82°C (177°F).
Full opening temperature 95°C (205°F).
Valve lift (at full open) 8.5 mm (0.33 inch) or more.