Accent GT Coupe L4-1495cc 1.5L DOHC MFI (1997)
Hose/Line HVAC: Vehicle Damage Warnings
HANDLING TUBING AND FITTINGS
The internal parts of the refrigeration system will remain in a state of chemical stability as long as pure-moisture tree refrigerant and refrigerant oil are
used. Abnormal amounts of dirt, moisture or air can upset the chemical stability and cause troubles or even serious damage.
The following precautions must be observed
1. When it is necessary to open the refrigeration system, have everything you will need to service the system, ready so the system will not be left
open any longer than necessary.
2. Cap or plug all lines and fittings as soon as possible to prevent the entrance of dirt and moisture.
3. All lines and components in parts stock should be capped or sealed until they are ready to be used.
4. Never attempt to rebind formed lines to fit. Use the correct line for the installation.
5. All tools, including the manifold gage, the gage set manifold and test hoses should be kept clean and dry.