8. Remove the radiator and fan assembly.
9. Disconnect the discharge pipe and the liquid tube (A) from the condenser.

NOTE
a. Cap the open fittings immediately to keep moisture from entering the system.
b. Be careful not to damage the discharge tube and the liquid tube (A).
c. Be careful not to damage the condenser fins.

10. Remove two condenser mounting bolts.
11. Remove the condenser assembly.

INSTALLATION

1. Installation is the reverse of removal.
2. If the condenser is replaced with a new unit, add 25 cc of compressor oil to compressor.
3. Evacuate, charge and test the refrigeration system.