hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Component Inspection|Page 4561 > < Diagram Information and Instructions|Page 4558
Page 1
background image

Canister Purge Solenoid: Testing and Inspection
Component Inspection

INSPECTION

NOTE:  When disconnecting the vacuum hose, make a mark on it so that it can be reconnected to its original position.

1. Disconnect the vacuum hose from the solenoid valve.
2. Detach the harness connector.

3. Connect a vacuum pump to the nipple to which the red striped vacuum hose was connected.

4. Apply vacuum and check when voltage is applied to the evaporative emission canister purge solenoid valve and when the voltage is discontinued.

5. Measure the resistance between the terminals of the solenoid valve.

EVAP Canister Purge Solenoid Valve:
Coil resistance : 26 ohm [at 20 °C (68 °F)]

Component Inspection|Page 4561 > < Diagram Information and Instructions|Page 4558