hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 7233 > < Diagram Information and Instructions|Page 7231
Page 1
background image

Condenser Fan: Testing and Inspection

Fig. 6  Condenser Fan Relay Terminal Identification

1. Using a volt-ohm meter, ensure there is no continuity between terminals "L" and "B", Fig. 6.
2. Apply 12 volts across terminals S1 and S2, then check for continuity between terminals "L" and "B". Replace as necessary.

Diagram Information and Instructions|Page 7233 > < Diagram Information and Instructions|Page 7231