Elantra L4-1595cc 1.6L DOHC 16 Valve (1995)
Fig. 2 Control Relay Testing
2. Connect a 12V power supply (-) terminal to the terminal 10 of the control relay and check the continuity between terminals 3 and 4 when the (+)
terminal is connected to and disconnected from the terminal 7.
Fig. 3 Control Relay Testing
3. Connect a 12V power supply (+) terminal to the terminal 3 of the MFI control relay and measure the voltages at the terminal 4 when the (-)
terminal is connected to and disconnected from the terminal 9.
4. If one of the above is improper, replace the MFI control relay.