hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Sensors and Switches - Emission Control Systems > < Positive Crankcase Ventilation Valve|Specifications|Page 5278
Page 1
background image

Positive Crankcase Ventilation Valve: Service and Repair

REMOVAL & OPERATIONAL INSPECTION 

1. Disconnect the ventilation hose from the positive crankcase ventilation (PCV) valve. Remove the PCV valve from the rocker cover and reconnect

it to the ventilation hose.

2. Run the engine at idle and put a finger on the open end of the PCV valve and make sure that intake manifold vacuum is felt.

NOTE: The plunger inside the PCV valve will move back and forth.

3. If vacuum is not felt, clean the PCV valve and ventilation hose in cleaning solvent or replace if necessary.

VISUAL INSPECTION 

1. Remove the positive crankcase ventilation valve.

2. Insert a thin stick into the positive crankcase ventilation valve from the threaded side to check that the plunger moves.

3. If the plunger does not move, the positive crankcase ventilation valve is clogged. Clean it or replace.

INSTALLATION 

Install the positive crankcase ventilation valve and tighten to specified torque.

Tightening torque: 8-12 Nm (5.8-8.7 lb.ft.) 

Sensors and Switches - Emission Control Systems > < Positive Crankcase Ventilation Valve|Specifications|Page 5278