hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Evaporator Temperature Sensor / Switch|Specifications|Page 528
Page 2
background image

8. With the thermostatic switch connector in coupled state, install a voltmeter between 2 and 3 (-) terminal and check whether there is change in

voltage between terminals according to the temperature of the evaporator surface.

* Thermostatic switch operating characteristics

NOTE:  This check should be carried out on the back probes of the thermostatic switch when it is in coupled state.

9. It above condition is not satisfied, remove the evaporator unit and replace the thermostatic switch. Refer to Evaporator Case, Service and

Repair.

10. After inspection, install all the removal parts. Installation is the reverse order of removal.

Refrigerant Pressure Sensor / Switch, HVAC > < Evaporator Temperature Sensor / Switch|Specifications|Page 528