Battery: Technical Service Bulletins
Electrical - Battery Testing/Equipment/Warranty Info.

Group: ENGINE ELECTRICAL

Number: 10-EE-003

Date: AUGUST 2010 

Model: ALL MODELS

Subject
GR8 DIAGNOSTIC BATTERY TESTER/CHARGER TOOL & NEW BATTERY WARRANTY POLICY

DESCRIPTION:
The Midtronics GR8-1270 Diagnostic Battery Tester/Charger Assembly launches in August 2010 as a new Hyundai required tool. A new Hyundai
Battery Warranty Policy requires that GR8 be used for all battery warranty claims according to procedures outlined by the service procedure of this
bulletin. Claims based on the Midtronics MCR-570 handheld tester will no longer be accepted.

This bulletin describes how to use the GR8 for battery related warranty repair work. The GR8 is a state of the art tool that checks battery health, then
performs a reliable intelligent safe charge which can quickly restore some batteries to good condition. For example a dead battery that has not been at a
low state of charge for a long period, may be fully revived within 1.5 hours and not make replacement necessary.

Basic Operation and Battery Warranty Policy using GR8:

1. Perform a quick test in the Battery Test mode. If the Battery Test mode provides a "Replace Battery result the battery can be replaced without further

steps.

2. If the Battery Test mode produces a "Charge and Retest result, you are then required to conduct a Diagnostic Charge that will determine whether the

battery is able to be brought to a "Good Battery condition by a full GR8 charge. If the initial diagnostic charge test finds that the charge will not
revive the battery it usually will indicate "Replace Battery on average within 20 minutes.

3. Should the battery pass the "Diagnostic Charge test, it will continue charging to full battery charge condition (which can take up to 1.5 hours) and

indicate "Good Battery" when completed successfully.

4. The GR8 produces printouts of the results in both the Battery Test and Diagnostic Charge modes. Both printouts must be attached to the warranty

repair order with proper VIN and RO number entered via GR8's keyboard.

NOTE:

This new Battery Warranty Policy requires you to always perform a Diagnostic Charge after a Battery Test result of "Charge and Retest".

GR8 Diagnostic Battery Tester/Charger Assembly:

Electrical - Battery Testing/Equipment/Warranty Info.|Page 1308 > < Brakes - Rear Drum Brake Wheel Cylinder Leak Inspection|Page 1302