Santa Fe L4-2.4L (2001)
Refrigerant: Service and Repair
Always conduct a leak test with an electronic leak detector whenever leakage or refrigerant is suspected and when conducting service operations which
are accompanied by disassembly or loosening or connection fittings.
NOTE: In order to use the leak detector properly, read the information provide to perform the specific maintenance and inspection.
If a gas leak is detected, proceed as follows:
1. Check the torque on the connection fittings and, if too loose, tighten to the proper torque. Check for gas leakage with a leak detector.
2. If leakage continues even after the fitting has been tightened, discharge the refrigerant from the system, disconnect the fittings, and check their
seating faces for damage. Always replace, even if the damage is slight.
3. Check the compressor oil and add oil if required.
4. Utilize a partial charge of the system to recheck for gas leaks. If no leaks are found, evacuate and charge the system again.