Santa Fe L4-2.4L (2001)
NOTE:
After the adaptive values have been reset (erased), an "adaptive learning" procedure must be completed as shown below.
3. Attach a Hi-Scan Pro or GDS and select "Engine" menu, "Current Data" menu and throttle position sensor in volts ("THROTTLE POS. SENSOR",
"ACCEL. P0S. S", or "ACCEL PEDAL 1 VOLT", depending on model).
4. Drive the vehicle until the ATF temperature is within the temperature range shown.
5. Request an assistant to monitor the Hi-Scan while accelerating the vehicle at small throttle openings (approximately 25-30% throttle). Hold the
accelerator pedal steady at a throttle position sensor value of 1.45~1.75v during several 1-2-3-4 upshifts.
Repeat until normal gear transitions occur.
6. Repeat this procedure for 4-3, 3-2 and 2-1 downshifts.