Variable Valve Timing Actuator: Service and Repair

Removal

1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the CVVT oil control valve connector (A).
3. Remove the installation bolt (B), and then remove the valve from the engine.

[Bank 1 / Intake]

[Bank 1 / Exhaust]

Installation

CAUTION:

-

Install the component with the specified torques.

-

Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

CAUTION:

-

Apply the engine oil to the valve O-ring.

1. Installation is reverse of removal.

CVVT oil control valve installation bolt:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)

Vehicle Speed Sensor > < Engine Control System|Page 3630