Scoupe L4-1468cc 1.5L SOHC (12 VALVE) Turbo (1995)
Measure the resistance between the high-voltage terminal for the No.1 and No.4 cylinders, and between the high-voltage terminals for the No.2
and No.3 cylinders.
Standard value: 12.1 ± 1.8 K Ohms
CAUTION: Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.