hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Central Control Module|Testing and Inspection|Page 7 >
Page 1
background image

Central Control Module: Testing and Inspection

Central Control Module

Operation Check of Components

While operating the components, check whether the operations are normal with timing chart.

1. Variable intermittent wiper

Time specification
T1 : Max. 0.7 sec.
T2 : Time of wiper motor 1 rotation.
T3: 1.5 ± 0.7 sec. (VR=0kOhms) - 10.5 ± 3 sec. (VR=50 k ohms)

2. Washer

1. Time specification 

T1 : 0.6 sec
T2 : 2.5 - 3.8 sec

2. This function should be operated preferentially even though the variable intermittent wiper is operating.

3. Rear window defogger

Time specification 
T1: 20 ± 3 Min.

4. Seat belt warning

Time specification
T1,T2: 6 ± 1 sec.
T3: 0.3 ± 0.1 sec.