Tucson AWD L4-2.4L (2010)
Variable Valve Timing Actuator: Service and Repair
Removal
1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the CVVT oil control valve connector (A).
3. Remove the installation bolt (B), and then remove the valve from the engine.
[Bank 1 / Intake]
[Bank 1 / Exhaust]
Installation
CAUTION:
-
Install the component with the specified torques.
-
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
CAUTION:
-
Apply engine oil to the valve O-ring.
1. Installation is reverse of removal.
CVVT oil control valve installation bolt:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)