hyundai Workshop Repair Guides

Hyundai Workshop Service and Repair Manuals

Control Assembly, HVAC|Service and Repair > < Rear Control Panel|Page 6782
Page 2
background image

(2) Continuance operation : DTC code is more two.

(3) STEP operation

A. Normal or one fault code is same as a continuance operation.
B. DTC code as more two.

4. If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
5. Fail safe In-car temperature sensor:

(1) Control with the value of 25°C(77°F)
(2) Ambient temperature sensor: Control with the value of 20°C(67°F)
(3) Evaporator temperature sensor: Control with the value of -2°C(28.4°F)
(4) Water temperature sensor : Control with the value of -2°C (28.4°F)
(5) Temperature control actuator (Air mix potentiometer):

If temperature setting 17°C-24.5°C, fix at maximum cooling position.
If temperature setting 25°C-32°C, fix at maximum heating position

(6) Mode control actuator (Direction potentiometer):

Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.

(7) Intake control actuator :

Fix fresh position, while selecting fresh mode.
Fix recirculation position, while selecting recirculation mode.

(8) AQS sensor : AQS operation OFF.

Intake position : The position before selecting AQS switch.

Control Assembly, HVAC|Service and Repair > < Rear Control Panel|Page 6782