infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Lamps and Indicators - Engine > < Tightening Torques & Sequences|Page 2341
Page 5
background image

Tighten in numerical order as shown in the figure.
<-: Engine front
^

There are two types of mounting bolts. Refer to the following for locating bolts.
M8 x 90 mm (3.54 inch) 7, 8
M8 x 35 mm (1.38 inch)  Except the above

Intake Manifold (Upper) 

Tighten in numerical order as shown in the figure. 
<-: Engine front

Electric Throttle Control Actuator 
^

Install gasket with its directional protrusion set up/downward. 

^

Tighten mounting bolts of electric throttle control actuator equally and diagonally in several steps. 

^

After installation perform procedure in EM-182, INSPECTION AFTER INSTALLATION.

Water Hose 
Insert hose by 27 to 32 mm (1.06 to 1.26 inch) from connector end. 

INSPECTION AFTER INSTALLATION 
^

Perform the Throttle Valve Closed Position Learning when harness connector of electric throttle control actuator is disconnected. Refer to
EC-744, Throttle Valve Closed Position Learning. See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Programming and Relearning/Throttle Valve Closed Position Learning

^

Perform the Idle Air Volume Learning and Throttle Valve Closed Position Learning when electric throttle control actuator is replaced. Refer to
EC-744, Idle Air Volume Learning. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Programming and
Relearning/Idle Air Volume Learning

Lamps and Indicators - Engine > < Tightening Torques & Sequences|Page 2341