infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

High-Pressure Flexible Hose|Page 1776 > < High-Pressure Flexible Hose
Page 2
background image

5. Remove mounting nut from high-pressure flexible hose (compressor side), and then remove high-pressure flexible hose.

CAUTION:  Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of air.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:

-

Replace O-rings of high-pressure flexible hose with new ones, and then apply compressor oil to it when installing it.

-

Female-side piping connection is thin and easy to deform. slowly insert the male-side piping straight in axial direction.

-

Insert piping securely until a click is heard.

-

After piping connection is completed, pull male-side piping by hand to make sure that connection does not come loose.

-

When recharging refrigerant, check for leaks.

High-pressure flexible hose bracket mounting bolt : 5.5 N.m (0.56 kg-m, 49 in-lb)

High-Pressure Flexible Hose|Page 1776 > < High-Pressure Flexible Hose