FX45 AWD V8-4.5L (VK45DE) (2006)
c.
Turn the ignition switch OFF for 10 seconds.
d.
Turn the ignition switch "ON" for 2 seconds then
e.
Turn the ignition switch "OFF" again for 10 seconds (see Figure 2).
f.
Proceed with step 6.
Perform Idle Air Volume Learning (IAVL)
NOTE:
Make sure all electrical loads are turned OFF, including A/C, defroster, radio, lights, etc. while performing the following procedures. Also, make
sure the engine cooling fans are NOT operating during the following procedures.
6.
Perform the Idle Air Volume Learning procedure as follows:
a.
Connect CONSULT-II to the vehicle.
b.
Warm up engine and transmission to operating temperature.
c.
In the [CONSULT WORK SUPPORT] mode, select [IDLE AIR VOL LEARN]. See Figure 3.
NOTE:
^
If IDLE AIR VOL LEARN is not shown as a SELECT WORK ITEM on CONSULT, the vehicle does not need the procedure.
^
In this case only, this bulletin is complete, no further action is needed.