Audible Warning Device: Component Tests and General Diagnostics

Combination Meter

POWER SUPPLY AND GROUND CIRCUIT

COMBINATION METER : Diagnosis Procedure

1.CHECK FUSE
Check for blown fuses.

Is the inspection result normal?
YES  -  GO TO 2.
NO  -  Be sure to eliminate cause of malfunction before installing new fuse.
2.CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector terminal and ground.

Is the inspection result normal?
YES  -  GO TO 3.
NO  -  Check harness between combination meter and fuse.
3.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector.
3. Check continuity between combination meter harness connector terminal and ground.

Is the inspection result normal?
YES  -  INSPECTION END
NO  -  Repair harness or connector.

Unified Meter And A/C Amp.

POWER SUPPLY AND GROUND CIRCUIT

UNIFIED METER AND A/C AMP. UNIFIED METER AND A/C AMP. : Diagnosis Procedure

1.CHECK FUSE
Check for blown fuses.

Initial Inspection and Diagnostic Overview|Page 7160 > < Initial Inspection and Diagnostic Overview|Page 7158