Tighten mounting bolts in two steps in numerical order as shown in the figure.

1st step: 10.1 Nm (1.0 kg-m, 7 ft-lb)
2nd step: 23.6 Nm (2.4 kg-m, 17 ft-lb)

6. Connect injector sub-harness.
7. Install fuel sub tube mounting bolt.
8. Connect fuel feed hose (with damper).
-

Handling procedure of O-ring is the same as that of fuel damper and fuel sub-tube.

-

Insert fuel damper straight into fuel sub-tube.

-

Tighten mounting bolts evenly in turn.

-

After tightening mounting bolts, check that there is no gap between flange and fuel sub-tube.

9. Connect quick connector between fuel feed hose (with damper) and centralized under-floor piping connection as follows:

a. Check that no foreign substances are deposited in and around centralized under-floor piping and quick connector, and that there is no damage

to them.

b. Thinly apply new engine oil around centralized under-floor piping from tip end to spool end.
c. Align center to insert quick connector straightly into centralized under-floor piping.

-

Insert quick connector to centralized under-floor piping until top spool is completely inside quick connector and 2nd level spool exposes right
below quick connector.

CAUTION:
-

Hold align center to avoid inclined insertion to prevent damage to O-ring inside quick connector.

-

Insert until you hear a "click" sound and actually feel the engagement.

-

To avoid mis-identification of engagement with a similar sound, be sure to perform the next step.

d. Pull quick connector by hand holding position (A). Check it is completely engaged (connected) so that it does not come out from centralized

under-floor piping (1).

e. Install quick connector cap (3) to quick connector connection.