The materials listed in the Rule 1151 Regulated Areas chart above can also be used in non-regulated areas.

VOC COMPLIANCE

At the issue time of this bulletin, the VOC compliance of the products listed above is considered accurate. Please consult your paint system supplier for
specific VOC compliance information as VOC regulations can change from time to time.

If your paint system supplier does not have Infiniti-approved NCLC refinish products, you can get specific technical advice from the local distributor of
one of the approved paint suppliers.

To locate a local distributor, receive specific technical advice, or if you have any difficulty obtaining refinish materials, you may contact the corporate
office of the approved paint suppliers at the following telephone numbers:

AKZO-Sikkens.........................................................................................................................................................................................1-404-441-8975 028
BASF (Glasurit-RM).......................................................................................................................................................................................1-800-825-3000
DuPont............................................................................................................................................................................................................1-800-222-5225
Herberts Standox.............................................................................................................................................................................................1-800-551-9296
ICI...................................................................................................................................................................................................................1-800-647-6050
Spies Hecker....................................................................................................................................................................................................1-516-777-7100
PPG.................................................................................................................................................................................................................1-216-572-6111
Acme...............................................................................................................................................................................................................1-800-928-8650
Martin-Senour.................................................................................................................................................................................................1-800-526-6704
Sherwin-Williams............................................................................................................................................................................................1-800-798-5872

NOTE:

Products from different suppliers should not be intermixed. Current refinish materials are designed to work as a system. If your current paint supplier
is not approved and you need to obtain refinish materials from one of the approved paint suppliers, you must also purchase the necessary primers,
reducers, hardeners and base coats from that distributor.

SERVICE PROCEDURE

When repairing a panel with the NCLC refinish products, follow the guidelines below. For more specific assistance on materials, application or VOC
compliance please contact your paint supplier at the numbers referenced in this bulletin.

PREPARATION

1.

Clean and dry panel or repair area.

2.

Using an appropriate wax and grease remover, clean any contaminants from the panel.

3.

Abrade the panel surface as recommended by the supplier of your paint.

4.

Thoroughly clean the abraded area.

WARNING:

Approved refinish materials contain isocyanates. Follow all manufacturer safety precautions.

MATERIAL APPLICATION

1.

Mask off overspray area.

2.

Final clean and degrease surface. Follow with a tack cloth wipe.

3.

Apply basecoats and clear coats as recommended by your paint suppler.

POLISHING