M35 V6-3.5L (VQ35DE) (2006)
NOTE:
^
"Battery Voltage" is the voltage level of CONSULT-II's battery.
^
"Charger Input" is the voltage level of the vehicle's battery. (It MUST be between 12 and 13.5 V.)
3.
* Adjust the battery charger voltage (charge rate) so the Charger Input is between 12 V and 13.5 V.
^
Make sure the battery charger is adjusted so it will continue to charge for the entire reprogramming time; approximately 30 minutes.*
4.
As mentioned the Charger Input reading MUST be above 12 volts (see Figure 19 previously shown).
^
A reading above 12 volts confirms;
a.
The DLC-II is properly connected to the vehicle,
b.
The vehicle battery voltage is sufficient for ICC reprogramming,
c.
CONSULT-II has a sufficient power supply to perform ICC reprogramming.
^
If the vehicles battery voltage ("Charger Input" is below 12 volts one or more of the following may be the cause:
a.
The battery charger is not charging the battery (poor connection or it is not working) or the charge rate is set to low.
b.
The DLC-II does not have a good connection to the ICC reprogramming cable (not straight).
c.
The ICC reprogramming cable does not have a good connection to the ICC control unit or the vehicle harness.
d.
The DLC-II or ICC reprogramming cable may have a malfunction (damaged wire or pins).
e.
The CONSULT-II Converter (J44200-50 / black box) is not working correctly (see Figure 15).
CAUTION:
^
Do not attempt ICC reprogramming if the vehicle's battery voltage is below 12 volts.
^
Permanent ICC damage can occur if the vehicle battery does not maintain the minimum voltage during ICC reprogramming.
^
If Charger Input is above 12 volts power from the vehicle battery will keep CONSULT-II's power supply at the correct level during
reprogramming (see Figure 19).
^
If the charging voltage is too high (above 13.5 V) there may be a risk of damaging electrical components such as the ECU etc.
4.
Continue with Section 4 below.
Section 4: Check CONSULT-II Converter version
1.
Press [BACK] two times.