QX4 2WD V6-3.5L (VQ35DE) (2003)
Distance Sensor: Adjustments
Setting the ICC Target Board
SETTING THE ICC TARGET BOARD
Accurate ICC target board setting is required for the laser beam aiming adjustment.
CAUTION: ICC system does not function normally if laser beam aiming is not accurate.
Adjusting Height of The Target
1. Attach a triangle scale as shown in the figure.
2. Adjust the height of the target stand so that the point of the triangle aims the center of the ICC sensor.
Adjusting The Right-left Position of The Target
1. Attach a scale (at least 300 mm [12 in] or longer) or stick as shown in the figure.