Refrigerant Pressure Sensor / Switch: Description and Operation
Operation

Refrigerant Flow

Refrigerant Pressure Sensor

The refrigerant system is protected against excessively high or low pressures by the refrigerant pressure sensor, located on the condenser. 

If the system pressure rises above, or falls below the specifications, the refrigerant pressure sensor detects the pressure inside the refrigerant line and
sends the voltage signal to the ECM. ECM makes the A/C relay go OFF and stops the compressor when pressure on the high pressure side detected by
refrigerant pressure sensor is over about 2,746 kPa (28 kg/sq.cm, 398 psi) or below about 177 kPa (1.8 kg/sq.cm, 26 psi).