S-Type (X200) V8-4.2L (2005)
-
GO to Pinpoint Test G195523p19. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p19
The module Does Not Respond to the Jaguar approved diagnostic system - powertrain control module.
Possible Source(s):
-
Wire or connection in the ISO 9141 network.
-
ECM.
Action(s) to take:
-
GO to Pinpoint Test G195523p20. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p20
U2003. The module Does Not Respond to the Jaguar approved diagnostic system - voice activated control module (VACM).
Possible Source(s):
-
Wire or connection in SCP network.
-
VACM.
Action(s) to take:
-
GO to Pinpoint Test G195523p21. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p21
U2008. The module Does Not Respond to the Jaguar approved diagnostic system - phone module.
Possible Source(s):
-
Wire or connection in the SCP network.
-
Wire or connection in the D2B network.
-
phone module.
Action(s) to take:
-
GO to Pinpoint Test G195523p22. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p22
P1573, P1609, P1777. Sympathetic DTCs from modules in CAN network.
Possible Source(s):
-
DTCs set as a result of DTCs from other modules in CAN network.
Action(s) to take:
-
GO to Pinpoint Test G195523p23. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p23
U2003, The module Does Not Respond - compact disc changer (CDDJ).
Possible Source(s):
-
Fibre optic or connection in the D2B network.
-
CDDJ.
Action(s) to take:
-
GO to Pinpoint Test G195523p24. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p24
U2008, The module Does Not Respond - phone module.
Possible Source(s):
-
Fibre optic or connection in the D2B network.
-
phone module.
Action(s) to take:
-
GO to Pinpoint Test G195523p25. See: Testing and Inspection/Pinpoint Tests/Pinpoint Tests (P Code Charts)/P Code Charts (Pinpoint
Tests)/PINPOINT TEST G195523p25
U2019, The module Does Not Respond - voice activated control module. (VACM).
Possible Source(s):