Vanden Plas L6-4.0L (1990)
Transmission Position Switch/Sensor: Adjustments
Rotary Switch Adjust
1.
With selector lever in N position, remove rotary switch protective cover (1), Fig. 5.
2.
Loosen mounting bracket bolts and remove rubber plug from switch (2), Fig. 5.
3.
Install rotary switch setting tool No. JD-161 or equivalent, to align switch rotor with switch body.
4.
After alignment, evenly tighten switch securing bolts.